CIP Circuit Data Sheet | Shengtu

CIP Circuit Data Sheet

Seven numbers per circuit are what a CIP quotation actually turns on. Fill them in here and the sheet works out the return-line duty needed to hold velocity, tells you whether a static spray device covers the vessel, and prints a circuit list you can paste straight into an enquiry. Nothing is sent anywhere — the sheet runs in your browser.

One Circuit at a Time

1.5 m/s is the floor we build to.

We size contact time at 20 to 45 minutes.

Your Circuit Sheet

CircuitBoreReturn duty Spray deviceContact shareSoil
No circuits added yet.

What the Sheet Assumes

Return duty is the volumetric flow a round bore has to carry to reach the velocity you asked for: the bore area multiplied by the velocity, converted to cubic metres per hour. It is a geometry calculation, not a pump selection — pump duty also has to cover the static head and the losses in your pipe run, which is the part we work out from the layout.

The spray-device call uses the effective-diameter figure we publish on the main page: one static spray device covers roughly 2.4 m. Above that a rotary jet head is the honest answer, because a static device wets by flooding while a rotary head puts mechanical energy on the wall.

Nothing here replaces a quotation. Send the sheet and a process engineer replies within one business day with the circuits grouped, the cycle assumed and the parameters set.